Product Details:
Parameter | HV |
Display Type | Digital |
Model Name/Number | QS-1M |
Dimension | 405 X 290 X 480 MM |
Brand | Qualitech Systems |
Automation Grade | Semi-automatic |
Weight | 40 KG |
Hardness Scale | HV |
Warranty | 1 YEAR |
Voltage | 220 V |
Test Range | 5 HV To 3000 HV |
Test Force | 10 g{0.098N}, 25g{0.245N}, 50g{0.49N}, 100g{0.98N}, 200g{1.96N}, 300g{2.94N}, 500g{4.9N},1000g{9.8N |
I Deal In | New Only |
Model | QS-1M | QS-1A | ||
Turret | Manual Turret | Automatic Turret | ||
Testing force | 10g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N ), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N) Test force error: ±1.0% | |||
Hardness scale | HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1 | |||
Loading speed | ≤0.05mm/sec | |||
Indenter | Standard Rectangular pyramid diamond indenter (136º±0.5º) | |||
Min. measuring unit | 0.25μm | |||
Hardness value rang | 5HV-3000HV | |||
Hardness Value of Reading | Digital LCD Screen | |||
Eyepiece | 10X manual analog eyepiece | |||
Objective lens | 10X (observe), 40X (Measurement) | |||
Total magnification | 100X (For Observation) , 400X (For Measurement) | |||
Loading method | Automatically (Load, dwell and unload the testing force) | |||
Duration time | 1-60s (each step is 1 second) | |||
Maximum height | 90mm | |||
Throat depth | 95mm | |||
Instrument size and Net weight | 405*290*480mm (L×W×H) 40kg | |||
Packing size and Gross weight | 580x345x580mm( LxWxH) 55kg | |||
Light Source | LED cold light source | |||
Power Supply | 220V + 5%, 50/60 Hz (110V is available) | |||
X-Y Testing Table | Dim.:100×100 mm, Max. Travel Range: 25×25mm, Moving Resolution Ratio: 0.01mm | |||
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 | |||
Standard Accessories |
1 piece: Weights shaft; 10X manual micrometer eyepiece; 10X and 40X | |||
Optional Accessories | Camera & Auto Hardness Measurement software, Knoop Indenter, Thin Specimen Test Table, Flat fixture, Digital XY Micrometer (L.C. 0.001mm) |
Additional Information:
Testing force | 10 g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N ), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N) |
Hardness conversion scale | HRA, HRB, HRC, HRD, HK, HBS, H15N, H3ON, H45N, H15T, H30T, H45T |
Min. measuring unit | 0.25pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 400X (For Measurement) (Can be extended to 150X or 600X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Automatic |
Maximum height | 85mm |
Throat depth | 115mm |
Instrument size and Net weight | 490x185x515mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information:
Testing force | 10 g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N ), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N) |
Hardness conversion scale | HVO.01, HVO.025, HVO.05, HVO.1, HVO.2, HVO.3, HVO.5, HV1 |
Min. measuring unit | 0.01 pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 400X (For Measurement) (Can be extended to 150X or 600X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Manual |
Maximum height | 85mm |
Throat depth | 115mm |
Instrument size and Net weight | 490x185x515mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
) Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information:
Testing force | 10 g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N ), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N) |
Hardness conversion scale | HVO.01, HVO.025, HVO.05, HVO.1, HVO.2, HVO.3, HVO.5, HV1 |
Min. measuring unit | 0.01 pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 400X (For Measurement) (Can be extended to 150X or 600X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Automatic |
Maximum height | 85mm |
Throat depth | 115mm |
Instrument size and Net weight | 490x185x515mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information:
Testing force | 10 g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N ), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N) |
Hardness conversion scale | HVO.01, HVO.025, HVO.05, HVO.1, HVO.2, HVO.3, HVO.5, HV1 |
Min. measuring unit | 0.01 pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 400X (For Measurement) (Can be extended to 150X or 600X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Automatic |
Maximum height | 85mm |
Throat depth | 110mm |
Instrument size and Net weight | 490x185x515mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
) Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information:
Testing force | 200g (1.96N), 500g (4.9N), 1000g (9.8N), 2000g (19.6N), 3000g (29.4N), 5000g (49N |
Hardness conversion scale | HRA, HRB, HRC, HRD, HK, HBS, H15N, H3ON, H45N, HI5T, H30T, H45T |
Min. measuring unit | 0.02 pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 200X (For Measurement) (Can be extended to 150X or 300X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Manual |
Maximum height | 85mm |
Throat depth | 115mm |
Instrument size and Net weight | 490x185x570mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information:
Testing force | 200g (1.96N), 500g (4.9N), 1000g (9.8N), 2000g (19.6N), 3000g (29.4N), 5000g (49N |
Hardness conversion scale | HRA, HRB, HRC, HRD, HK, HBS, H15N, H3ON, H45N, HI5T, H30T, H45T |
Min. measuring unit | 0.02 pm |
Hardness value range | 1HV-4000HV |
Hardness Value of Reading | Digital LCD Screen (62x44mm) |
Total magnification | 100X (For Observation) , 200X (For Measurement) (Can be extended to 150X or 300X) |
Loading method | Automatically (Load, dwell and unload the testing force) |
Duration time | 1-99s (each step is 1 second) |
Turret | Automatic |
Maximum height | 85mm |
Throat depth | 115mm |
Instrument size and Net weight | 490x185x570mm (LxWxH) 43kg |
Light Source | LED Cold light source (can be continuous use for 24 hours, no heat generate ensure stable working, servicing life can reach 100,000 hours) |
X-Y Testing Table | Dim.:100x100 mm, Max. Travel Range: 25x25mm, Moving Resolution Ratio: 0.01mm (Digital X-Y Testing Table with digital LCD Screen for Optional) |
Data Output | Built-in Printer; Built-in RS-232 interface (transfer data to computer, easy for long time save) |
Executed Standard | GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 |
Standard Accessories | 1 piece: 10X micrometer eyepiece ; 10X and 40X objective lens; Vickers indenter; X-Y Testing Table; Flat fixture; sheet specimen fixture, Small parts fixture; Gradienter; Data transfer software; Data line; Power line; Dust cover; Manual Book; Certificate of quality; Warranty Card; Accessory case 2 pieces: Standard block of hardness 4 pieces: horizontal adjusting screw |
Additional Information: